PipeForgev1.1
Butt-Weld Take-Off
Field

Quick Take-Off

C–C

Result

cut pipe
Pipe cut length
— in
—
enter a measurement
Take-off A—
Take-off B—
Root gap—
Welds—
cut = measurement − take-off A − take-off B − gaps
Developed by Bryan Leurquin

Multi-Segment Run

up to 6
Total pipe to cut
—
Developed by Bryan Leurquin

Butt-Weld Theory

ASME B16.9
LR 90° = NPS × 1.5 → 8" = 12"
SR 90° = NPS × 1.0 → 8" = 8"
LR 45° = NPS × 5/8 → 8" = 5"
head-math: 8÷2=4, 4÷2=2, 2÷2=1, 4+1 = 5"

Multipliers are editable on the Standards tab. cut = measurement − take-off A − take-off B − one root gap per welded end.

Fitting center-to-end (in)

B16.9
NPSLR90SR90LR45Tee

Valve end-to-end (in)

Cl.150
NPSGateGlobeCheckBall

Class set by the Valve class selector on Quick Calc. Take-off = end-to-end ÷ 2 (working point at valve center). Verify against product data sheet.

Developed by Bryan Leurquin

Shop Standards

saved on device

Set your shop's elbow multipliers and default gap. Everything recalculates live and persists on this device.

Custom Fittings

your own

Custom fittings appear in the A/B selectors. Take-off is the fixed center-to-end you enter (a welded end — root gap still applies).

Developed by Bryan Leurquin

Butt-Weld End Prep

open root
Bevel angle37.5° ± 2.5°
Included angle75°
Root face (land)1/16" nominal
Root opening (gap)1/16" – 3/32"

Fit-up & weld sequence

  1. Bevel both ends to 37.5°, dress a clean 1/16" land, wire-brush to bright metal 1" back.
  2. Set the root gap (match your selected gap), line up with a clamp, check hi-lo.
  3. Tack 3–4 places; feather the start/stop of every tack.
  4. Root pass — steady keyhole; grind any suck-back.
  5. Hot pass, then fill passes, then an even cap.
  6. Inter-pass clean between passes; control inter-pass temp on alloy/SS.

General guidance. Bevel, land, gap, filler and pass sequence are governed by the qualified WPS for the material, wall thickness and process on your job.

Developed by Bryan Leurquin

Measurement Modes

pick the right one

C–C — both ends fittings; measured center to center. Two welds, two take-offs.

C–E — one fitting, one bare end. One weld, one take-off.

E–E — both bare. No take-off — cut equals what you measured.

F–F — measured between fitting faces. Just the root gaps.

Words

Center-to-end: fitting centerline to the weld face — the take-off in butt-weld.

Root gap: the opening for the root pass; cut the pipe short by it.

Cut length: what you actually cut the pipe to.

Developed by Bryan Leurquin

Saved Take-Offs